1. Fit a variety of motor types (asynchronous induction motors, permanent magnet synchronous motors, reluctance motors)
2. Low frequency and large output torque, 200%
3. Quick response, 10ms rapid acceleration
4. Realize zero speed position lock and enhanced hover function
AS Series |
| ||||
Model | AS500 High Performance Vector Drives | ||||
Applicable Motor (kW) | 400V class2.2-560 | ||||
Overload Class | 150%, 60s | ||||
Output frequency | V / F control: 0.00-300.00 Hz | ||||
PG card power | 5V, 12V, 300mA | ||||
PG card signal | Open collector, push-pull, differential, SIN / COS incremental, Endot Absolute, | ||||
Applicable Motor Type | Induction motor | SPM synchronous motor, IPM synchronous motor, servo motors | |||
Control method | V / F control | Open loop | Closed loop | Open loop | Closed loop |
Starting torque | 2.50Hz 150% | 0.5Hz 150% | 0.00Hz 150% | SPM: 5% rate, 150% | 0.00Hz, 200% |
Speed range | 1:50 | 1: 200 | 1: 1000 | 1: 100 | 1: 1500 |
Steady speed accuracy | ± 2% | ± 0.2% | ± 0.02% | ± 0.2% | ± 0.02% |
Torque accuracy | ± 5% (closed loop control) | ||||
Torque Control | Torque / speed control can be switched through terminals, with multiple torque setting modes | ||||
Zero servo control | It can realize zero speed position locking, precise positioning and position control | ||||
Built-in brake unit | 22kW And below | ||||
Built-in DC reactor | 22KW and above | ||||
Applications | Heavy industrial and construction machinery load, 1.5 times overload
|
1. Fit a variety of motor types (asynchronous induction motors, permanent magnet synchronous motors, reluctance motors)
2. Low frequency and large output torque, 200%
3. Quick response, 10ms rapid acceleration
4. Realize zero speed position lock and enhanced hover function
AS Series |
| ||||
Model | AS500 High Performance Vector Drives | ||||
Applicable Motor (kW) | 400V class2.2-560 | ||||
Overload Class | 150%, 60s | ||||
Output frequency | V / F control: 0.00-300.00 Hz | ||||
PG card power | 5V, 12V, 300mA | ||||
PG card signal | Open collector, push-pull, differential, SIN / COS incremental, Endot Absolute, | ||||
Applicable Motor Type | Induction motor | SPM synchronous motor, IPM synchronous motor, servo motors | |||
Control method | V / F control | Open loop | Closed loop | Open loop | Closed loop |
Starting torque | 2.50Hz 150% | 0.5Hz 150% | 0.00Hz 150% | SPM: 5% rate, 150% | 0.00Hz, 200% |
Speed range | 1:50 | 1: 200 | 1: 1000 | 1: 100 | 1: 1500 |
Steady speed accuracy | ± 2% | ± 0.2% | ± 0.02% | ± 0.2% | ± 0.02% |
Torque accuracy | ± 5% (closed loop control) | ||||
Torque Control | Torque / speed control can be switched through terminals, with multiple torque setting modes | ||||
Zero servo control | It can realize zero speed position locking, precise positioning and position control | ||||
Built-in brake unit | 22kW And below | ||||
Built-in DC reactor | 22KW and above | ||||
Applications | Heavy industrial and construction machinery load, 1.5 times overload
|
Power input | Input voltage | 380-460V (-15% ~ + 10%), three-phase power |
Input Frequency | 45-65Hz | |
Allowable voltage fluctuation | Voltage unbalance <3% | |
Instant-drop | Three-phase AC380-460VWhen the power supply input voltage <AC300V when, after 15ms undervoltage protection | |
Power output | Voltage | Input voltage 0VAC ~ |
Overload Class | Stable 40 ℃, heavy duty 150%, 1min | |
Efficiency (full load) | ≥0.94 | |
Output frequency accuracy | ± 0.01% (digital command -10 ~ + 45 ℃) ; ± 0.1% (simulation instruction 25 ± 10 ℃) | |
Digital I / O | Opto-isolated input | 7road, 24V high active low can be set, input function can be defined |
Open collector | 2road,Output functions can be defined | |
Relay output | 2-way, normally open contacts, contact capacity: inductive, 1.5A / 250VAC, output function defined | |
Analog I / O | Analog Input Voltage | 2-way,Accuracy 0.1%; Voltage:-10V~ + 10VDCOr Current: 0-20mA optional signal |
Analog voltage output | 2-way,Accuracy 0.1%; Voltage:-10V~ + 10VDCOr Current: 0-20mA optional signal | |
Control characteristics | Carrier frequency | 1.1-8 kHz; load characteristics, the carrier frequency can be automatically adjusted |
Frequency setting resolution | 0.01Hz (digital command),± 0.06Hz / 120Hz (11bit + unsigned analog instruction) | |
Run command channel | Given the operation panel, a given control terminal, a given communication | |
Given channel frequency | Given the operation panel, the digital / analog given, a given communication, performance function given | |
Torque boost | Automatic torque boost; Manual torque boost | |
V / F curve | Custom V / F Curve linear V / F And three curves of torque-derating | |
Automatic voltage regulation (AVR) | Automatically adjusts the output according to the fluctuation of the bus voltage PWM Duty cycle signal, thereby reducing the influence of voltage fluctuations of the output voltage ripple | |
Instantaneous stop non-stop processing | When the instantaneous power by bus voltage control, to achieve uninterrupted operation | |
DC braking capacity | Braking current:0.0~120.0% Of rated current | |
Special feature | Parameter copy | Standard operating panel can achieve parameter upload, download, copy-progress indicator |
Process PID | It can be used for closed-loop control of the process variable | |
Common DC bus | Full range enabling more than one common DC bus power converter | |
Motor protection | Locked rotor | |
Motor overload | ||
Speed limit | ||
Drive protection | Output current limit | |
Inverter overload | ||
IGBT I²t overload | ||
Input Supply Undervoltage / Overvoltage | ||
DC bus under-voltage / overvoltage | ||
IGBT overheating | ||
Radiator overheating | ||
electricity failure |
Power input | Input voltage | 380-460V (-15% ~ + 10%), three-phase power |
Input Frequency | 45-65Hz | |
Allowable voltage fluctuation | Voltage unbalance <3% | |
Instant-drop | Three-phase AC380-460VWhen the power supply input voltage <AC300V when, after 15ms undervoltage protection | |
Power output | Voltage | Input voltage 0VAC ~ |
Overload Class | Stable 40 ℃, heavy duty 150%, 1min | |
Efficiency (full load) | ≥0.94 | |
Output frequency accuracy | ± 0.01% (digital command -10 ~ + 45 ℃) ; ± 0.1% (simulation instruction 25 ± 10 ℃) | |
Digital I / O | Opto-isolated input | 7road, 24V high active low can be set, input function can be defined |
Open collector | 2road,Output functions can be defined | |
Relay output | 2-way, normally open contacts, contact capacity: inductive, 1.5A / 250VAC, output function defined | |
Analog I / O | Analog Input Voltage | 2-way,Accuracy 0.1%; Voltage:-10V~ + 10VDCOr Current: 0-20mA optional signal |
Analog voltage output | 2-way,Accuracy 0.1%; Voltage:-10V~ + 10VDCOr Current: 0-20mA optional signal | |
Control characteristics | Carrier frequency | 1.1-8 kHz; load characteristics, the carrier frequency can be automatically adjusted |
Frequency setting resolution | 0.01Hz (digital command),± 0.06Hz / 120Hz (11bit + unsigned analog instruction) | |
Run command channel | Given the operation panel, a given control terminal, a given communication | |
Given channel frequency | Given the operation panel, the digital / analog given, a given communication, performance function given | |
Torque boost | Automatic torque boost; Manual torque boost | |
V / F curve | Custom V / F Curve linear V / F And three curves of torque-derating | |
Automatic voltage regulation (AVR) | Automatically adjusts the output according to the fluctuation of the bus voltage PWM Duty cycle signal, thereby reducing the influence of voltage fluctuations of the output voltage ripple | |
Instantaneous stop non-stop processing | When the instantaneous power by bus voltage control, to achieve uninterrupted operation | |
DC braking capacity | Braking current:0.0~120.0% Of rated current | |
Special feature | Parameter copy | Standard operating panel can achieve parameter upload, download, copy-progress indicator |
Process PID | It can be used for closed-loop control of the process variable | |
Common DC bus | Full range enabling more than one common DC bus power converter | |
Motor protection | Locked rotor | |
Motor overload | ||
Speed limit | ||
Drive protection | Output current limit | |
Inverter overload | ||
IGBT I²t overload | ||
Input Supply Undervoltage / Overvoltage | ||
DC bus under-voltage / overvoltage | ||
IGBT overheating | ||
Radiator overheating | ||
electricity failure |
· Heavy industrial and construction machinery load, 1.5 times overload
· Metal processing machinery: expanding machine, stamping machine, forging machine, milling machine
· Construction machinery: concrete mixer, brick making machine
· Mine machinery: mine hoist, ball mill
· Material storage / handling / conveying: three dimensional warehouse, belt conveyor, brick in / out machine
· Heavy industrial and construction machinery load, 1.5 times overload
· Metal processing machinery: expanding machine, stamping machine, forging machine, milling machine
· Construction machinery: concrete mixer, brick making machine
· Mine machinery: mine hoist, ball mill
· Material storage / handling / conveying: three dimensional warehouse, belt conveyor, brick in / out machine